The C-arm is then placed in a right anterior oblique (RAO) position of about 20-30 degrees. This allows the stomach wall to be visialized as the needle pushes on and then punctures the gastric wall. The appropriate position for the G tube is selected on the skin surface and marked. Three T-fasteners are then prepared for placement. The T-fasteners will be deployed into the lumen of the stomach and then pulled up to keep the stomach against the anterior abdominal wall while the G tube site is dilated and the tube is placed.